Modbus Register Information (Only Support RS485 Modbus Model ) |
Parameters
Function |
Register Add. (HEX/DEC) |
PLC Add.
(Index Number) |
Note |
RTU Device ID |
0x0064/ 100 |
65 |
Factory Default RTU ID:01, Available Range: 1~254 |
Modbus Baud Rate |
0x0065 / 101 |
66 |
0:1200; 1:2400; 2: 4800; 3:9600 (Default); 4:19200
Baud Rate, No Parity Check, 8 bits, 1 parity check |
Soil Moisture |
0x0000 / 0 |
1 |
Function Code: 3/ 4; UNIT 16, R/O; 0~100.0% |
Temperature |
0x0001 / 1 |
2 |
Function Code:3/ 4, UNIT 16, R/O; -200~ 800 (-20.0 ~ 80.0˚C) |
Electric Conductive |
0x0002 / 2 |
3 |
Function Code:3/ 4, UNIT 16, R/O; 0~20000 (0~2000us/cm) |
pH |
0x0003/ 3 |
4 |
Function Code:3/ 4, UNIT 16, R/O; 30~100 (3.0~ 10.0 pH) |
Nitrogen |
0x0004/ 4 |
5 |
Function Code:3/ 4, UNIT 16, R/O; 0~2000 (0~2000mg/ Kg) |
Phosphate |
0x0005/ 5 |
6 |
Function Code:3/4, UNIT 16, R/O; 0~2000 (0~2000mg/ Kg) |
Potassium |
0x0006/ 6 |
7 |
Function Code:3/4, Unit 16, R/O; ; 0~2000 (0~2000mg/ Kg) |
Salinity |
0x0007/ 7 |
8 |
Function Code:3/4, Unit 16, R/O; ; 0~2000 (0~2000mg/ Kg) |
Total Dissolved Solids |
0x0008/ 8 |
9 |